Es50-22b

FEP Tubing (Fluoropolymer)
Inch size (Series TIH) is introduced.
Heat resistance:200°C
Series TH/ TIH
It changes according to the operating pressure.
Applications
Refer to the graph of the max. operating pressures on page 1, 2.
General pneumatic piping
Color variations
Semiconductor
Medical care
Automobile

Translucent
Certified to current
Food Sanitation
Size variations
Legislation
Metric size: ø4 to ø12
Ministry of Japanese Health and
Inch size: 1/8" to 3/4" (ø3.18 to ø19.05)
Safety, directive #370,1959
FEP Tubing (Fluoropolymer)
Metric Size

Series TH
TH0402 TH0425 TH0604 TH0806 TH1075 TH1008 TH1209 TH1210
Tubing O.D. (mm)
Tubing I.D. (mm)
Translucent
Red (Translucent)
Blue (Translucent) BU
Black (Opaque)
Specifications
How to measure the
minimum bending radius.

One-touch fittings: Series KQ, KJ Insert fittings: Series KF Applicable
fittings
Miniature fittings: Series M, MS (Hose nipple type) Max. operating 100°C
pressure (MPa) 200°C 0.4
Refer to below “Max. Operating Pressure.” Min. bending
radius (mm)
Operating temperature
Air, Inert gas: -20 to 200°C Water: 0 to 100°C (No freezing) the other end closer. Measure 2R at the point where the Material
FEP (Fluorinated Ethylene Propylene Resin) outside diameter's rate of change is 5%.
Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure. A surge pressure higher than the maximum operating pressure can cause breakage of the fittings, or rupture of the tubing.
Furthermore, an abnormal temperature increase due to adiabatic compression can also result in ruptured tubing.
Max. Operating Pressure
Note 2) Do not use in locations where the FEP tubing will move.
Be sure to operate under the maximum operating pressure conditions using the lower maximum operating specification of either the tubing or fittings.
After long term use or under high temperatures, some fittings leakage may occur due to material deterioration with age. Perform periodic inspections, and if any leakage is detected, replace with a new product immediately.
(Refer to maintenance part of "Tubing Precautions" on the Back page 2.)Refer to Best Pneumatics catlog Vol. 15 for all other precautions.
For High Purity Fluoropolymer, refer to the precautions of CAT.ES70-17, "High Purity Fluoropolymer Fittings & Note 3) Minimum bending radius is measured as shown left as representative values.
Allow extra length when piping since the tubing may crush if bent more than the min. bending radius. TH0806/TH1075/TH1209
How to Order
Metric size
TH1008/TH1210
Indication of tubing model
Length per roll
Color indication
100 Note)
Note) The maximum operating pressure varies dependant on the I.D. bore size even if the O.D. is the same.
FEP Tubing (Fluoropolymer)
Inch Size

Series TIH
TIHA01 TIHB01 TIHC01 TIHA05 TIHB05 TIHA07 TIHB07 TIHA11 TIHB11 TIH13
Tubing O.D. mm
0.093" 0.086" 0.065" 0.137" Tubing I.D.
2.36 2.18 1.65 3.48 3.15 4.57 3.95 6.99 6.33 Translucent
Red (Translucent)
Blue (Translucent) BU
Black (Opaque)
Specifications
How to measure the
minimum bending radius.
Applicable fittings
One-touch fittings: Series KQ, KJ Fluoropolymer fittings: Series LQ Max. operating
pressure (MPa)
200°C
Refer to below “Max. Operating Pressure.” Min. bending
radius (mm)
Operating temperature
Air, Inert gas: -20 to 200°C Water: 0 to 100°C (No freezing) the tubing into a U shape. Fix one end and gradually move Material
FEP (Fluorinated Ethylene Propylene Resin) the other end closer. Measure 2R at the point where the Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure. A surge pressure higher than the maximum operating pressure can cause breakage of the fittings, or rupture of the tubing.
Furthermore, an abnormal temperature increase due to adiabatic compression can also result in ruptured tubing.
Note 2) Do not use in locations where the FEP tubing will move.
Be sure to operate under the maximum operating pressure conditions using the lower maximum operating Max. Operating Pressure
specification of either the tubing or fittings.
After long term use or under high temperatures, some fittings leakage may occur due to material deterioration with age. Perform periodic inspections, and if any leakage is detected, replace with a new product immediately.
(Refer to maintenance part of "Tubing Precautions" on the Back page 2.)Refer to Best Pneumatics catlog Vol. 15 for all other precautions.
For High Purity Fluoropolymer, refer to the precautions of CAT.ES70-17, "High Purity Fluoropolymer Fittings & Note 3) Minimum bending radius is measured as shown left as representative values.
Allow extra length when piping since the tubing may crush if bent more than the min. bending radius. TIHB05/TIHB11
TIHA01/TIHB01/TIHA05
How to Order
TIHA07/TIHA11/TIH13
Inch size
Indication of tubing model
Length per roll
Color indication
Note) 100ft (33m) roll is available with Note) The maximum operating pressure varies dependant on the I.D. bore size even if the O.D. is the same.
Chemical Resistance of the
Fluoropolymer FEP Material

Chemicals in this table are inactive against FEP material Note 1), however physical properties may be
effected by temperature or pressure change.
Please make sure that operating conditions do not cause problems since the use of FEP tubing under
chemical environment is unsecured.

Note 1) “Inactive in chemistry terminology” means - not to cause any chemical reaction.
Reference cited: Teflon®, the fluoropolymer handbook, Manual for the chemical applications of Teflon®. Du Pond-Mitsui Fluorochemicals Co., Ltd. Teflon® is a registered trademark for the fluoropolymer produced by E.I du Pond de Nemours & Company (Inc.) and Du Pond-Mitsui Fluorochemicals Co., Ltd.
Series TH/TIH
Safety Instructions
These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by a
label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe
ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices.
Caution : Operator error could result in injury or equipment damage.
Warning : Operator error could result in serious injury or loss of life.
Danger : In extreme conditions, there is a possible result of serious injury or loss of life.
Note 1) ISO 4414: Pneumatic fluid power -- General rules relating to systems Note 2) JIS B 8370: Pneumatic system axiom 1. The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility with the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system.
2. Only trained personnel should operate pneumatically operated machinery and
equipment.
Compressed air can be dangerous if handled incorrectly. Assembly, handling or maintenance of
pneumatic systems should be performed by trained and experienced operators.
3. Do not service machinery/equipment or attempt to remove components until
safety is confirmed.
1. Inspection and maintenance of machinery/equipment should only be performed once measures to
prevent falling or runaway of the driven object have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system.
3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston 4. Contact SMC if the product is to be used in any of the following conditions:
1. Conditions and environments beyond the given specifications, or if product is used outdoors.
2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuit in press applications, or safety equipment.
3. An application which has the possibility of having negative effects on people, property, or animals, Series TH/TIH
Tubing Precautions
Be sure to read before handling. Refer to back page 1 for safety instructions.

Selection
Air Supply
1. Confirm the specifications.
1. Types of fluid
The products appearing in this catalog are designed for use only in This product is designed for use with compressed air. Consult with compressed air systems (including vacuum).
SMC if a different fluid is to be used.
Do not use outside the specified ranges of pressure, temperature, Consult with SMC regarding products for use with general purpose etc., as this may cause damage or malfunction. (Refer to fluids, to confirm which fluids can be used.
2. When there is a large amount of drainage.
SMC cannot assure the product quality when fluids other than air, Compressed air containing a large amount of drainage can cause the malfunction of pneumatic equipment. An air dryer or Drain Catch should be installed upstream from filters.
2. In case of using the product for medical care
3. Drain management
This product is designed for use with compressed air system If air filter drains are not flushed regularly, the drainage will flow applications for medical care purposes. Do not use in contact with downstream leading to the malfunction of pneumatic equipment.
human bodily fluids, body tissues or transfer applications to a In cases where the management of drain flushing will be difficult, the use of filters with automatic drains is recommended.
For details on the quality of compressed air mentioned above, refer to SMC's "Best Pneumatics" catalog vol. 14.
1. Do not use in locations where the connecting threads and tubing connection will slide or rotate. The connecting theads and tubing connection will come apart under these conditions.
Use rotary type one-touch fittings (Series KS, KX) in cases where sliding or rotation will occur. Only air can be used as the operating Operating Environment
fluid, when using rotary type one-touch fittings.
2. Use tubing at or above the minimum bending radius. Using below the minimum bending radius can cause breakage or flattening of the tubing.
1. Do not operate in locations in an explosive atmosphere.
3. Never use the tubing for anything flammable, explosive or toxic 2. Do not operate in locations where vibration or impact occurs.
such as, gas, fuel gas, or cooling mediums, since the contents can 3. In locations near heat resources, block off radiant heat.
Maintenance
Mounting
1. Check for the following during regular maintenance, and replace 1. Before mounting confirm the model and size, etc. Also, confirm that there are no blemishes, nicks or cracks in the product.
a) Scratches, gouges, abrasion, corrosion 2. When tubing is connected, consider factors such as changes in the tubing length due to pressure, and allow sufficient leeway.
c) Twisting, flattening or distortion of tubing 3. Mount so that fittings and tubing are not subjected to twisting, d) Hardening, deterioration or softness of tubing pulling or moment loads. This can cause damage to fittings and flattening, bursting or disconnection of tubing, etc.
2. Do not repair or patch the replaced tubing or fittings for reuse.
4. Mount so that tubing is not damaged due to tangling and abrasion. 3. When using insert or miniature fittings over a long period, some This can cause flattening, bursting or disconnection of tubing, etc.
leakage may occur due to age deterioration of the materials. Perform periodic inspections, and if any leakage is detected, correct the problem by additional tightening. If tightening becomes ineffective, replace the fittings with a new product immediately.
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. Not allowing chips of the piping thread or the seal material to go in.
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK
SLOVAKIA
SMC Priemyselná Automatizáciá, s.r.o.
AUSTRIA
SMC Pneumatik GmbH
SLOVENIA
THAILAND
SPAIN/PORTUGAL
NORTH AMERICA
SWITZERLAND
SMC Corporation (Mexico) S.A. de C.V.
GERMANY
SMC Pneumatik GmbH
SOUTH AMERICA
ARGENTINA
HONG KONG
INDONESIA
NETHERLANDS
MALAYSIA
VENEZUELA
PHILIPPINES
SINGAPORE
AUSTRALIA
SMC Industrial Automation Polska Sp.z.o.o.
SMC Pneumatics (Australia) Pty. Ltd.
SOUTH KOREA
NEW ZEALAND
RUSSIA
SMC Pneumatik LLC.
1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPANTel: 03-3502-2740 Fax: 03-3508-2480URL http://www.smcworld.com 2004 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice 1st printing HV printing IW 120KS Printed in Japan.
and any obligation on the part of the manufacturer.
This catalog is printed on recycled paper with concern for the global environment.

Source: http://www.smcpneumatics.ie/binary/1/5/31/408/409/attachment/TH_TIH.pdf

jongekunstkritiek.nl

Voorlopig zonder titel (een schets over Scarlett Johansson, tussenruimte en moralisme) Bart Groenendaal, (NL, 1975) In de film Lost in Translation ontwikkelen Scarlett Johansson en Bill Murray een ijle, zwak-erotische vriendschap op basis van een gedeelde landerigheid. Hoewel er in de titel met het woord ‘lost’ naar die toestand wordt verwezen komen de karakters tot bloei in de luwte w

lfnc.org

BAY AREA LUPUS FOUNDATION plans recognize how valuable the benefit isand are working very hard to maintain an NEW LAWS NEXT YEAR TO PROTECT CONSUMERS don’t examine whether the health plan paysto obtain medications and insurers trying to Published September 29, 1998, keep a lid on costs has led to numerous con- Los Angeles Times sumer complaints, and resulted in new laws Dr

Copyright ©2018 Drugstore Pdf Search